Single CT model outperforms Merlin, trained only on routine radiology reports
A preprint describes one model that flags about a thousand findings across many kinds of CT scan, points to where it sees them and drafts a report. It learned all three tasks from ordinary hospital reports, with no hand-drawn lesion outlines.
scienceunderway.com/articles/single-ct-model-outperforms-merlin-trained-only-on-routine-radiology-reports

AI illustrationWhat the study shows
Computed tomography (CT) scans are 3D X-ray images. Most AI tools for CT cover one organ, one disease or one type of scan. This preprint, which has not been peer reviewed, describes a model called FORA. It aims to cover all of them at once. It was built by the company Forithmus with university partners and NVIDIA researchers.
The model reads every image series in an exam. It estimates the chance that each of 1,028 findings is present, from brain atrophy to kidney stones. For each finding it produces a map of the scan regions that drove the prediction. A language model then writes the report from those findings, maps and images.
The training signal came only from routine reports. A language model turned 341,581 reports from one Turkish hospital network into structured labels. The model then learned to link each exam-level label to parts of the scan, a method called multiple-instance learning, which treats a scan as a bag of small pieces and learns which pieces matter.
On 36,619 held-out exams from the same network, FORA scored 0.918 on AUROC, a 0 to 1 score of how well a model separates present from absent findings. The best of 18 released CT models scored 0.705. FORA led in every one of 12 scan types.
On outside data, it ranked first on three public test sets. On the test set released with Merlin, a well-known CT model, FORA scored 0.907 against Merlin's 0.826, with no training on that institution's scans.
For location, the authors checked FORA's strongest evidence point against expert outlines it never saw. It fell inside the lesion for about seven in ten blood clots in the lung and kidney masses, and nearly six in ten rib fractures. It did far worse on very small lesions and broad chest findings.
For reports, an automated checker found FORA recovered about three times as many of the radiologist's findings as NVIDIA's NV-Reason-CT, the strongest rival. An AI judge preferred FORA's report in about three in four head-to-head comparisons.
Our reading
In our reading, the main claim is less about raw scores and more about the recipe. Expert lesion outlines are slow and costly to produce. Reports exist for every scan. If reports alone can teach a model to recognise, locate and describe findings, then broad CT tools no longer wait on annotation budgets. The results here are a credible first case for that.
The location maps matter for trust. A report sentence that comes with a highlighted region can be checked in seconds. For example, a radiologist reading a draft that mentions a kidney stone could jump straight to the marked spot rather than search the whole scan. That is a practical way to catch AI errors, though the paper has not tested it with radiologists.
We rate this Readiness level III, open source available. The authors say trained models and code are public on GitHub, and the model beat others on public benchmarks. It does not reach level IV: there is no documented use at a named hospital and no prospective study.
The rest of this story is for members. Membership is free: read it at scienceunderway.com/articles/single-ct-model-outperforms-merlin-trained-only-on-routine-radiology-reports
Read the rest of this story
Membership is free. You get every article in full, and can save stories and follow topics.
We send a sign-in link, no password needed. Already a member? Sign inReadiness assessment
| Level | Status | Evidence |
|---|---|---|
| I Lab only | Met | A working model with trained weights and full methods, tested beyond the lab setting described in the paper. |
| II Benchmarked | Met | Results on public benchmarks: Merlin test set, RAD-ChestCT, CT-RATE (classification), plus FUMPE, KiTS23, RibFrac and ReXGroundingCT (localisation), compared with 18 CT models. Several comparisons are on the authors' own held-out set and use the authors' own LLM-judge scoring. |
| III Open source | Met | The paper says trained FORA models and code are public at https://github.com/forithmus/FORA. The chest radiograph dataset is on Hugging Face. The CT dataset is not fully released: it is on request, with a Docker-based evaluation service. I could not check the repository contents or licence. |
| IV In production | Not yet | The paper names an API and a viewing tool (Litera) but gives no documented deployment by a named hospital or customer, and no prospective or reader study. |
What would move it up
Level 4 needs documented use by a named hospital or company, or at least a prospective study. A blinded radiologist reader study on report accuracy and reading time would help most. Testing on scans from other health systems, with human review of the evidence maps, would also strengthen the case.
The study
Sezgin Er, Utku Turkbey, Alperen Gur et al.. Reliable and grounded reporting of any computed tomography scan with FORA. arXiv, 24 November 2026. Read the paper
Notes
- Er S, Turkbey U, Gür A, et al. Reliable and grounded reporting of any computed tomography scan with FORA. arXiv preprint, 24 November 2026. Not peer reviewed. Licence CC BY-NC-SA 4.0. Source
- Code and trained models, as stated by the authors (not checked by us). Source
- Chest radiograph dataset used to develop the method. Source
- Hosted evaluation on the held-out CT test set; models submitted as Docker containers. Source
- Key figures: macro AUROC 0.918 (95% CI 0.916 to 0.919) vs 0.705 for CoLiPri on 36,619 held-out exams; Merlin test set 0.907 vs 0.826; RAD-ChestCT 0.816 vs 0.796; CT-RATE 0.891 vs 0.871 (NV-Reason-CT, from its preprint). Top-focus hit rates: 69.7% FUMPE emboli, 72.8% KiTS23 renal masses, 66.1% renal cysts, 58.3% RibFrac, 27.6% ReXGroundingCT. Report macro recall 0.215 vs 0.066; judge score 0.570 vs 0.405; pairwise preference 73.8% vs 23.9%.
- Readiness: level III (Open source available). Public benchmark results and stated release of code and models; no documented deployment at a named organisation.
Edited and signed by
Stefan PerdalEditor and publisher142 stories editedStefan read the study, set the readiness level and approved this story. An AI system found the paper and wrote the first draft.
How this was made
An AI model read the study and wrote this article in the structure Science Underway uses. An editor reviewed it and approved it for publication. Check the original study before you rely on the details.
How we workNo corrections