In ESC cardiology answers, only half of GPT-4.1-mini's flagged errors were real
A hand audit of an AI fact-checking pipeline for European heart guidelines finds the checker is the weak link. Its own rewrites added about a third of the errors left in final answers.
scienceunderway.com/articles/in-esc-cardiology-answers-only-half-of-gpt-4-1-mini-s-flagged-errors-were-real

AI illustrationWhat the study shows
The authors built a pipeline that answers cardiology questions and then checks its own work. GPT-5.4 writes an answer from memory. GPT-4.1-mini splits the answer into single statements, called claims. It checks each claim against passages fetched from four European Society of Cardiology (ESC) guidelines. Claims judged wrong are rewritten, up to three times. This pattern is called verify-and-revise.
The test set has 160 questions, approved by a practising internist. Most are patient cases based on published case reports. Each question was run under four ways of fetching guideline text, three times each. The paper is a preprint and has not been peer reviewed.
The authors audited by hand all 606 claims the checker flagged as wrong. Only about 45% to 51% contradicted the guideline. The rest were checker mistakes, claims backed by other sources, or claims from an older guideline version. Counting every flag as a caught error would roughly double the real figure.
How the guideline text was cut up mattered. The best set-up stored each recommendation as its own passage and limited search to the right guideline section. It caught 47 of the 59 confirmed hallucinations. Single runs were unstable: one run caught only about two in five, while pooling three runs caught about three in four.
The rewrite step cut both ways. About two thirds of confirmed hallucinations ended fully fixed. But of 49 real errors left in final answers, 17 had been introduced by the rewrites. In the end, 1.7% of final answers still held a genuine error. The whole project cost about $52 in fees.
Our reading
In our reading, the main lesson is about measurement, not medicine. A checker model is itself a model, and it makes mistakes. When those mistakes are fed into a rewrite step, correct statements get changed into wrong ones. One example: a checker that wrongly rejects a correct blood-pressure target can push the system to replace it with a wrong one.
The errors the authors found were mostly near-misses, not inventions. About two in five confirmed hallucinations were shifted numeric cut-offs. Errors the checker missed looked similar, such as a heart-rate threshold of 175 instead of 170 beats per minute. That is the kind of slip a busy reader would not spot, and the kind that can change a clinical decision.
On our four-level readiness scale, we rate this level III, open source available. The authors say the dataset, code and audit files are public. We have not checked the repository. There is no documented use at any hospital or vendor.
The rest of this story is for members. Membership is free: read it at scienceunderway.com/articles/in-esc-cardiology-answers-only-half-of-gpt-4-1-mini-s-flagged-errors-were-real
Read the rest of this story
Membership is free. You get every article in full, and can save stories and follow topics.
We send a sign-in link, no password needed. Already a member? Sign inReadiness assessment
| Level | Status | Evidence |
|---|---|---|
| I Lab only | Met | A full pipeline was built and run on 1,920 arm-runs, with all runs completing. |
| II Benchmarked | Met | It is evaluated on a new 160-question, expert-approved benchmark over four ESC guidelines. Results include exhaustive human audit, a second-verifier study and a blind expert probe. The benchmark is new and released, not an established public benchmark. |
| III Open source | Met | The paper states that the dataset, corpus, pipeline code, notebooks, run payloads and audit workbooks are public at github.com/ilkinmasimov/esc-hallucination-qa. We have not checked the repository's contents. |
| IV In production | Not yet | There is no documented use by any hospital, vendor or other named organisation. |
What would move it up
Documented deployment or pilot use by a named clinical organisation, with measured error rates in real use. Before that, stronger evidence would include more than one clinician, comparison with external baselines, and models from other vendors.
The study
Ilkin Masimov, Rufana Baghirli, Muhammad Rashid. Mitigating Hallucinations in Medical Question Answering on ESC Cardiology Guidelines: Evaluation and Retrieval Optimization. arXiv, 25 November 2026. Read the paper
Notes
- Masimov, Baghirli and Rashid, 'Mitigating Hallucinations in Medical Question Answering on ESC Cardiology Guidelines: Evaluation and Retrieval Optimization', arXiv preprint, November 2026. Source
- Dataset, retrieval corpus, pipeline code, notebooks and audit files, as stated by the authors. Not checked by us. Source
- Exact figures: true-hallucination precision 44.7% to 50.6% across arms; single-run recall 35.6% to 41.2%; three-run union 71% to 80%; second-checker agreement 74.2%, Cohen's kappa 0.505; blind-probe miss rate 3.2% (95% CI 0.7% to 6.7%); genuine-error final answers 32 of 1,920 (1.7%); total cost $51.82.
- Readiness: level III, open source available (code and data released per the paper). Level IV not met: no documented use by a named organisation.
Edited and signed by
Stefan PerdalFounder. Twenty-five years of building digital products.173 stories editedStefan read the study, set the readiness level and approved this story. An AI system found the paper and wrote the first draft.
How this was made
An AI model read the study and wrote this article in the structure Science Underway uses. An editor reviewed it and approved it for publication. Check the original study before you rely on the details.
How we workNo corrections


